You are here: HARNESSES > TRITON (497) > Inspection Log

Inspection Log - TRITON

Initial / 180 Day Inspection

 

Serial Number  
Inspection Date  
Maintainer Name  
QA Inspector Name  
Maintainer Final Sign-off  
QA Sign Off QA 1_______ QA 2 _______ QA 3 ________ (Initial As Completed)

Maintainer / Inspector Notes

______________________________________________________________________________

______________________________________________________________________________

______________________________________________________________________________

Leak Test Recording / Adjustment Tables

  Shop Temperature Time Recorded Pressure
Begin Test      
End Test      

To determine corrected air pressure based on a change in shop temperature, apply the following equation:

Shop Temperature (In Fahrenheit) at Begin Test = A

Shop Temperature (In Fahrenheit) at End Test = B

Recorded Pressure at End Test = C

If the shop temperature decreased during the test:

(A — B)•.03 + C = ________ Corrected Air Pressure

If the shop temperature increased during the test:

C — (.03 • (B — A)) = ________ Corrected Air Pressure

Corrected Air Pressure must be 1.8 psi or greater.